Description
Reversed Phase C18 SPE Cartridges
Hawach Reversed Phase C18 SPE Cartridges have a high retention rate of the alkyl bonding phase for non-polar to moderate polar compounds. The hydrophobic reverse phase filler can retain most of the non-polar compounds and most of the organic analytes in the aqueous matrix.
C18 (end-capped) is a reversed-phase C18 SPE cartridge based on silica gel. It has the characteristics of high bonding density, low loss, and high recovery rate. C18 solid phase extraction cartridge is mainly used in the desalination of macromolecular samples such as drugs and their metabolites, proteins, and DNA in blood, plasma, and urine, and the enrichment of organic matter in environmental water samples.
The C18 (end-capped) solid phase extraction column uses octadecyl silica gel as the packing to retain non-polar compounds through strong hydrophobic interaction. The filler can retain most organic matter and is widely used in the environment, food safety, and other fields.
Advantage of Reversed Phase C18 SPE Cartridges
Multiple imported sorbent choices
Medical PP grade cartridges own high chemical compatibility
UHMW-PE made frits avoid contamination
Full range of packing size for choice
The wide range of pH
Octadecyl bond, end-capped
Strong hydrophobic selectivity
Increase the retention of alkaline substances
High carbon loading increases retention and higher recovery
Conducive to extract multiple analytes with different structures in the same sample
Suitable for retaining most organic compounds from aqueous substrates and biological matrices
Multiple cartridge volume and mode for choice
Applications of C18 Solid Phase Extraction Cartridge
Separation of biomolecules such as lipids, antibiotics, bile acids, and saccharides
Analysis of drugs, poisons, pollutants, and their metabolites in biological matrices
Determination of preservatives in cosmetics and skincare products
Determination of mycotoxins such as fumonisins in foods

Extracting Non-polar Compounds

Technical Data
Specification | Maximum Sample Load | Volume | Minimum Elution Volume |
---|---|---|---|
100-200mg | 5mg-10mg | 3mL | 200-500μL |
200mg-1g | 10mg-50mg | 6mL | 500μL-6mL |
500mg-2g | 25mg-100mg | 12mL | 3mL-10mL |
Ordering Information
Item No. | Specification | Package (pcs/pk) |
---|---|---|
SLSPE1001C18 | C18, 40-75μm, 60Å, 100mg/3mL | 100 |
SLSPE2003C18 | C18, 40-75μm, 60Å, 200mg/3mL | 50 |
SLSPE5003C18 | C18, 40-75μm, 60Å, 500mg/3mL | 50 |
SLSPE5006C18 | C18, 40-75μm, 60Å, 500mg/6mL | 30 |
SLSPE1K6C18 | C18, 40-75μm, 60Å, 1g/6mL | 30 |
SLSPE1K12C18 | C18, 40-75μm, 60Å, 1g/12mL | 20 |
SLSPE2K12C18 | C18, 40-75μm, 60Å, 2g/12mL | 20 |